About 50 results
Open links in new tab
  1. What is a full strength penetration weld? | Eng-Tips

    Jan 23, 2007 · Doesn't full penetration refer to a weld the full depth of the material being welded independant of strength? My interpretation is penetration is the distance your weld extends below the …

  2. MAX. PENETRATION, MAX. CONTACT FORCE ERROR and NEGATIVE …

    Sep 27, 2018 · Hello, I'm doing a simulation in abaqus standard and i wont to know if MAX. PENETRATION, MAX. CONTACT FORCE ERROR and NEGATIVE EIGENVALUES is a problem or …

  3. Pipe Penetration Through Concrete Slab | Eng-Tips

    May 15, 2020 · We will have a pipe penetration through the slab. Any suggestions on how to isolate the pipe from the slab? I was thinking of maybe wrapping the ductile iron pipe with some sort of asphalt …

  4. abaqus - solving penetration contact error between 2 surfaces

    Aug 31, 2012 · PENETRATION ERROR TOO LARGE COMPARED TO DISPLACEMENT INCREMENT. To solve I've tried the following: - lowering increments in Step to 1e-5 - I tried offsetting the one …

  5. pipe penetration on structural members | Eng-Tips

    Feb 27, 2010 · Hi guys, I need to prepare pipe penetration (vertical and horizontal) details on structural members (beams, slabs, walls and staircase). Any reference that you can suggest? Is there any …

  6. What is a full strength penetration weld? Part 2 | Eng-Tips

    Jan 30, 2007 · A full strength, penetration weld indicates that the workpieces are joined using a butt weld that completely fuses with each base metal being joined. In other words, the base metal strength is …

  7. SCIF Wall Penetration | Eng-Tips

    Apr 5, 2013 · Does anyone have any recommendations for how to penetrate a SCIF wall for a govt. project? Will a dielectric union be sufficeint, and are there good products for large pipe, 4" & larger?

  8. Roof Penetration detail through Metal Roof | Eng-Tips

    Sep 12, 2010 · Penetration-Free Attachment A first rule about any rooftop mounting is to do it without penetrating the roof membrane whenever possible. While this may seem obvious, on metal roofs, it …

  9. Penetration analysis | Eng-Tips

    Jul 10, 2003 · I am often performing extensive penetration-analyses for large steel-constructions. For the moment penetrations of girder-beams. I am looking for...

  10. Frost Penetration and Movement | Eng-Tips

    Oct 21, 2009 · Frost penetration and frost depth effects are really two different animals. As OldestGuy indicated, even in very cold climates, they recognize that footings do not have to go full depth of frost …